High-low temperature damp heat test chamber and water related fault solution

The temperature and humidity test of the high and low temperature damp heat test chamber and the water-related failure solution can not be separated from the water. In this article, I will give you a list of the high and low temperature damp heat test chambers that you have encountered in the past six years. Some water-related problems and related troubleshooting solutions.
Water-related problems are usually easier to solve. In many cases, the user can solve it himself or through the telephone guidance of our engineers. From the major categories of situations can be divided into water shortages and leakage. Water shortages are more common. Let's talk about water shortage first.
The situation of water shortage can be divided into water shortage in the water circulation system and lack of wet ball cloth.
1, water cycle water shortage. The lack of water in the water circulation cycle is mostly due to the lack of water in the tank. In this way, pure water is added to the tank until the water level gauge at the bottom right of the tank reaches about 80% of the entire scale.
However, I have encountered some special circumstances. Although this situation is very rare, I only appeared once in a six-year engineering career, but I still hope to talk about it here. There was a user feedback that the water in his tank was full, but the equipment was still off due to lack of water. In this case, it is thought that the water channel is not open. Causes the waterway to be blocked, possibly because the waterway is blocked by debris or the pump fails. The user's device is a new device that we have just sent to the past. Therefore, the situation of being blocked by contamination can be basically eliminated. Before the delivery of each equipment, we will all be able to do a full 7 days of commissioning. During the commissioning process, we have done ample tutorials on the internal systems, and the pump is certainly not a problem. Following the water-related circulation pipe, the customer told me that the water float (transparent) on the upper right side of the machine was waterless. This knows that the problem lies in this water level float. It may be that it is broken and it needs to be changed. However, the failure of the new machine float level has never occurred. Then I asked the user to remove the water level float and shake it. At this time, the entire water circulation system began to flow. It turns out that during the transportation process, due to the ups and downs of a device, the float ball and the water inlet below the ball were embedded and blocked the water inlet. By shaking the float out of the inlet, the water supply is normal. This situation usually occurs when a new machine arrives, or if the device is not parked for a long time.
2, wet ball cloth lack of water. This situation is more common. If the humidity keeps rising, even when it reaches 100%, the wet ball cloth is mostly deficient in water. This is usually an impurity in the water that precipitates on the wet ball cloth and loses its water absorption properties. So look at this time if the wet ball cloth is too dirty. If so, replace it with a wet ball cloth. If the wet ball cloth is new, there is still such a situation. Look at the wet ball tank for water. If not, it is a problem with the water circulation system. This detects the pump, and the fault condition of the floating ball described above. There is also an error that the operator does not often make. It should not be overlooked: The wet ball cloth does not have the bottom not soaked in the water in the damp cloth sink.
Leakage is mainly caused by the leakage of the waterway circulation and the wet ball a. The water leakage of the waterway. This results in the breakdown of the water tank and the water supply pipe, so that the gap can be repaired, or the related joints can be eliminated without leaking more water slides.
b. Wet bulb leakage. The wet ball slot is located under the wet ball cloth. For this situation, it is common that due to the unevenness of the ground, the wet ball tank is inclined to leak. This requires the replacement of a flat place on the ground. Of course, this situation should also be investigated from the inlet. There is an inlet valve for water supply to the wet ball tank. It is possible for the inlet valve to open relatively large. This can be observed by turning the inlet valve closer. There is also an error from the inside of the machine. The water level float box is placed too high. According to the principle of pressure, the water pressure in the wet ball tank rises, causing water overflow. This can be contacted by a professional engineer to adjust the float position.

Magnetic Separator

The Magnetic Separator is a machine to separate metals that contain magnet , such as iron pieces, soil blocks etc from materials like seed, grain, food etc.

We have three different types, the 5XCX series Magnetic Separator, Single Roller Magnetic Separator and Portable Magnetic Separator.

The 5XCX series Magnetic Separator has high magnet strength of 17000gauss, it can remove all magnet materials , for example, the soil blocks that contain magnet. It has one high strength roller with two normal rollers to drive one round belt, the grain will discharge into belt and spread on belt for sufficient processing, the magnetic materials and non magnetic materials will discharge from different outlet.

The Single Roller Magnetic Separator has one magnetic roller, magnet strength from 3000-8000guass. It is drived by electric motor, and has self-cleaning function.

The Portable Magnetic Separator is a portable type, without electric motor. It has one magnetic drum inside, when grain passing through it, the magnetic materials such as iron pieces will stick on the drum, so you need to clean it regularly. It can put on any machine or use independently, much convenient model.

Application: seed magnetic separator, bean magnetic separator, magnetic separator machine

Specification:

Magnetic Separator type

Capacity available

5XCX magnetic separator

5t/h

TCXD single roller magnetic separator

10-30t/h

TCXT portable magnetic separator

6-18t/h

FAQ:

1. How about payment terms?

Usually is 30%TT in advance, balance 70%TT before shipment. We also accept L/C at sight, Paypal, West Union, Money Gram etc.

2. How long is the delivery time?

15 days after payment

3. How about packaging?

We will pack machine into plywood box if ship by LCL. If ship by FCL, we will coat machine with plastic film and fixed well by belt fastener, strong iron wire and steel wedge etc.

4. Is there any warranty?

Warranty is 1 year.

5. Installation and commission?

We can send engineer to help installation and commissioning, but you should pay for visa, air tickets, salary and arrange food and hotel when our engineer in your country.

6. Do you have some videos that will help us on assemble or run the machines?

Yes, we have videos on how to assemble and use our machines, will send you a CD when ship the machine to you.

Magnetic Separator,Seed Magnetic Separator,Bean Magnetic Separator,Magnetic Separator Machine

SHIJIAZHUANG SYNMEC INTERNATIONAL TRADING LIMITED , https://www.seedgraincleaner.com