Tension electronic fence installation wiring details precautions!

Some problems that need to be considered during installation of the tension electronic fence and what needs to be paid attention to during the installation process! Today, let the guest Europe and everyone together point out one by one!
The first is when wiring and planning the tension fence! It should be ensured that there is no busy area in the protected area, that is, the formed warning area should be closed along the perimeter barrier.
In addition, in order to adapt to large campuses, bus-type tension electronic fences can be used, which can be extended to up to 16 poles depending on the terrain.
And in the division of the tension type electronic fence , it should be noted that it is conducive to the accurate positioning of the alarm, the length of the zone should be no more than 40m.
In the overall arming, the length of the large resistance fence area with more corners or more pulleys should be set to ensure that the most distal tension line of the zone is no more than 75mm.
As a tension electronic fence , the water quality of the tension line also determines whether the equipment alarm is accurate. A support rod should be installed every 3~5m in the middle of each zone of the tension type electronic fence. The base and the liner of all the support rods are installed. It should be firmly installed, and by adjusting the wire arranging device to ensure the level of the fence tension line of the anti-section, it is important to adjust the level of the tension line by adjusting the wire rod of the support rod.
The force- receiving rod at both ends of the tension type electronic fence and the unidirectional force-bearing rod base of the anti-section must be installed with a solid foundation and a balance force device. This is the prerequisite for ensuring reliable and stable operation of the tension fence.
According to the characteristics of tension perimeter, multi-functional tensioner, multi-directional base, dual-purpose pulley, horizontal and vertical pulley rod, single-channel pulley assembly, anti-torsion tension spring, adjustable support rod, base mounting positioning card, etc. Tension fence mounting kit.
A zoned force bar shall be installed at the corner of the wall of the tension electronic fence less than 120°. When the fence tension line in the zone is greater than or equal to 120° or the distance after the corner is shorter (more than 3m), the horizontal and vertical dual-purpose pulley rods can be used for transition. However, considering the transmission loss of the tension, the number of tension lines in one zone is not Should be more than 2 or more.
According to the different tension fence installation methods, there are different precautions!
When the tension type electronic fence is installed by " attachment" , the overall height of the fence is not less than 2 meters, and the height of the attached fence is not less than 750mm. The horizontal distance between the bottom tension line and the upper end of the solid perimeter should be 130mm~ 150mm, the spacing of other conventional adjacent two should be 200mm ± 10mm.
When the tension type electronic fence is installed in the " floor type" , the measuring lever, the force rod and the support rod should be reinforced. The height of the fence shall not be less than 1800mm, of which the tension cable below 1500mm, the distance between two adjacent bars shall be 150mm±10mm, and the tension cable of 1500mm or more shall be 200mm±10mm.
The tension fence “ grounded” installation needs to be configured with independent grounding. Specifically, a grounding pile is set under the lower main arm of each measuring rod. The standard of the pile is more than 40×40×4×1500mm (the grounding bolt or hole with more than m10) The standard galvanized grounding angle iron is driven vertically into the ground. The grounding pile body is reliably connected to the measuring rod and the uppermost tension wire of the corresponding control zone through the rvv16 wire. The grounding body should be buried in a place with relatively good conduction and grounding. The resistance is not more than 10Ω; if buried in a humid place, the grounding resistance should be no more than 4Ω.
Note: If there is strong electricity on site, the grounding point and the grounding point of the power line should be separated by more than 4 meters.
The above is a summary of the details that the customer needs to pay attention to during the installation of the tension electronic fence!